The efficient Radiant R1K 50 condensing boiler is optimized for heating. Using condensation for heat recovery, it offers high energy efficiency and requires a drainage system for the condensate.

Ideal for environments that require heating only, this boiler represents an effective and sustainable solution.

Annual Maintenance

Annual checks are crucial to ensure optimal boiler performance, maintaining efficiency, safety, and reliability. These annual checks are fundamental to ensure the safety and ongoing effectiveness of the device.

Boiler Checklist: Winter Preparation

  • Boiler Pressure Check: Verify the pressure via the pressure gauge to ensure optimal performance.
  • Thermostat Management: Check the batteries of the thermostat for accurate temperature regulation.
  • System Pressure: Ensure that the heating system pressure is appropriate, between 1 and 1.5 bar.
  • Professional Maintenance: Schedule professional maintenance for cleaning and inspection of your Radiant R1K 50 boiler.

Heating System Pressure Control

It's important to check quarterly that the system pressure is maintained between 1bar and 2bar. This check is also necessary in summer, as the boiler uses radiator water to heat sanitary water. Too low a pressure can interrupt the production of heating or hot water.

Use the filling tap, located under the appliance, to adjust the pressure. Open it until the pressure reaches 1.5bar, then close it.

Verify Temperatures

On the Radiant R1K 50 boiler, it is possible to adjust the heating temperature.

Attention to temperature adjustment:

  • The heating temperature adjustment refers to the radiator temperature and not the ambient temperature.

We suggest setting the temperature according to your needs and the time of year.

Boiler Safety During the Holidays

It's crucial to take some precautions with your Radiant R1K 50 boiler before leaving for the holidays to prevent accidents and problems. This also applies to the latest generation boilers.

Preventive actions:

  • Close the main water tap to avoid unexpected leaks.
  • Shut off the gas to increase the safety of your home.
  • Turn off the heat generator to limit unnecessary energy consumption.

Once you return, reactivate the settings by following the steps in reverse. You might need to restart the heat generator to cancel the shutdown errors.

With these simple steps, you can enjoy your vacation without worries, knowing that your boiler is safe and well managed.

Intuitive User Interface

The R1K 50 boiler stands out for its simple and intuitive user interface, thanks to the collaboration with NORDGAS. The Radiant's control panel is designed to be user-friendly, with clear buttons and a display that accurately reports errors, allowing for quick problem diagnosis and resolution.

Simple Error Diagnosis

Common errors such as no flame, thermal fuse interruption, or lack of water in the system are clearly reported on the display. This allows users to quickly identify the issue and take appropriate measures, such as reactivating the system or refilling the system. The boiler is also equipped with safety features like anti-freeze and preheating of sanitary water, ensuring optimal operation in all conditions.

  • Error 01: No flame, which can occur if the gas tap is closed or if the meter has been changed. Press the button. In all other cases, if it does not restart, call a technician.
  • Error 03: Flue side thermal fuse tripped. Press the button. If it does not restart, call a technician.
  • Error 04: No water in the system. Refill the system via the black cylindrical tap under the boiler, keep an eye on the pressure gauge above the display, and close the refill tap when the pressure reaches 1.2 or 1.5 bar. The error resets itself, followed by an approximately 2-minute venting procedure. Please wait.
  • Error 18: Insufficient circulation. This error may be caused by particularly dirty magnetic filters. Check the magnetic filter at the boiler inlet with a technician to restore the circulator flow rate.

Notifications

These refer not to errors but to functions currently in operation:

  • F08 Anti-freeze function for heating active: If the boiler is external and reaches a very low temperature, this procedure activates to prevent the technical water from freezing. Please wait for the operation to complete.
  • F33 System Venting Cycle: This usually happens during the reset of error E04. Once the Radiant R1K 50 boiler pressure is restored, it performs this function for about 2 minutes. Please wait for the operation to complete.
  • FH Fast H20: The boiler is preparing to preheat the sanitary water. Please wait for the procedure to complete.

Comfort and Sustainability in Noise and Consumption

The Radiant boiler series is designed with user comfort and environmental sustainability in mind. Their ultra-quiet operation, with noise levels of only 55 decibels, ensures unparalleled tranquility at home. From a sustainability perspective, these boilers excel in reducing gas and electricity consumption, with their 9 flame modulations for precise temperature control and the use of a high-efficiency modulating circulator. This combination of technologies makes Radiant's boilers an ideal choice for those seeking an eco-friendly and comfortable option.

Boiler Safety and Maintenance

It is important to subject the R1K 50 boiler to annual maintenance to ensure its efficiency and safety. Interventions on the boiler by unqualified people are strongly discouraged, as they can compromise the safety of the appliance. For any problem or anomaly, it is essential to turn to an expert technician. Remember that periodic maintenance by professionals is crucial for the longevity and safety of the appliance.

Regarding the Use of Electric Energy

  • Do not touch the appliance with wet or damp parts, or while barefoot
  • Do not pull on electrical cords
  • Do not expose the appliance to atmospheric agents such as rain, sun, etc., unless expressly provided for.
  • In case of damage to the cord, turn off the appliance and consult exclusively professionally qualified personnel for its replacement.

Safety Actions in Case of Gas Detection

If a gas odor is detected, it is fundamental to adopt these precautionary measures:

  • Do not use electrical appliances, including phones, that might generate sparks.
  • Immediately open doors and windows to facilitate air exchange.
  • Stop the gas supply by closing the taps.
  • Immediately request the intervention of a specialized technician.

It is important to use the R1K 50 boiler exclusively for the purposes for which it is designed, avoiding improper uses that can be dangerous. Ensure that any intervention on the boiler is carried out by qualified personnel to prevent accidents and maintain the warranty.

List of Components and Spare Parts

In this guide, you will discover everything there is to know about the different components and spare parts of the R1K 50 boiler: how to identify them, their specific function, and useful tips for maintenance and replacement.

Temperature Adjustment

On the control panel of the Radiant R1K 50 condensing boiler, you will find all the operating information. You can set the heating temperatures by pressing the + and - buttons next to the Radiator symbol. After pressing, the boiler displays the set temperature for a few seconds and then returns to the primary exchanger temperature.

Indeed, the boiler shows you the outgoing temperature, which can be interpreted as the internal temperature of the boiler and in winter as the actual temperature of the radiators.

Using the + and - buttons, you can choose the desired temperatures for heating. We suggest:

  • From 25°C to 38°C (maximum) if you have underfloor heating.
  • From 55°C to 65°C if you have aluminum or steel radiators.
  • From 45°C to 60°C if you have cast iron radiators.

Modulating Boiler Circulator Radiant R1K 50

Technological Innovation: The Modulating Pump for Boilers

The latest generation modulating pump, with adjustable speed from 0 to 100%, represents a qualitative leap in the efficiency of modern boilers. Managed by a sophisticated electronic system with a dedicated control connector, this pump enables optimization of energy consumption and reduction of management costs. Its ability to dynamically adapt to the system's needs not only ensures optimal performance but is also a fundamental requirement in new installations, highlighting the importance of this technology for a more sustainable and economical future.

3/8 Automatic Plastic Air Purger for Radiant R1K 50 boiler

Automatic Plastic Air Purger

The plastic automatic air purger, used as an insert in the purging housing in the pump manifold, is a key component in the Radiant R1K 50 boiler. This small element plays a vital role in ensuring the efficiency of the heating system by eliminating air from the system.

Made of durable plastic, this air purger is designed to easily fit into the dedicated housing in the pump manifold. Its use is particularly recommended to prevent air accumulation in the boiler's hydraulic circuitry, especially in systems with a lot of aluminum where this problem is more frequent after periods of inactivity (summer).

Regularly checking and replacing the air purger and the system pressure is essential for maintaining uninterrupted operation at the start of the heating season. Its functionality is crucial for the proper operation of the entire domestic heating system.

3/8 Automatic Air Purger for Radiant R1K 50 boiler

3/8 Automatic Air Purger

The 3/8 automatic air purger is a fundamental component in the Radiant R1K 50 boiler to ensure the elimination of air in the heating system. This small but essential device plays a critical role in maintaining the efficiency of the heating system.

Despite its low cost, this component is vital to ensure that there is no trapped air in the radiator system, especially for aluminum ones, where the presence of air can be a frequent problem, particularly after long periods of inactivity like during the summer.

Checking the functionality and replacing the air purger is always advised to prevent circulation problems at the beginning of the heating season. Its efficiency is crucial for the proper operation of the entire domestic heating system.

Safety Systems according to the ErP Directive

The construction and installation of boilers in Europe are strictly regulated by a series of European standards, aimed at ensuring safety, energy efficiency, and reduction of environmental impact.

One of the main reference regulations is the ErP (Energy-related Products) Directive, which imposes stringent requirements in terms of energy efficiency and emissions for all energy-related products, including boilers. This directive is accompanied by specific UNI EN standards for each type of boiler, detailing the technical and safety standards to be respected.

The R1K 50 boiler therefore includes:

The Safety Thermostat, located on the heating supply, intervenes by blocking the gas flow to the burner in case of overheating of the water in the primary circuit. It is essential to never deactivate this safety device.

The Flame Ionization Detector ensures safety by shutting down the boiler in case of gas absence or incomplete ignition of the main burner.

The Antifreeze Device activates the burner to maintain the water temperature above 5 °C, preventing freezing of the system.

The Hydraulic Safety Valve, set at 3 bar, protects the heating circuit. It is advisable to connect it to a siphoned drain and not use it to empty the circuit.

Possible Improvement Works

The condensing boiler Radiant R1K 50 requires special attention to the correct installation of the flue pipe. Especially in horizontal sections, condensation can form, compromising the functionality of the fan. It is not uncommon to see installations where the flue pipe (especially if corrugated) forms a siphon, causing the boiler to produce very loud noises. It is essential to have a qualified technician ensure that the pipes are in optimal condition.

Integrating a Gas Tap with a Test Well

Not always does the meter provide a connection for instrumental tightness testing. A useful tip is to replace the gas tap under the boiler with a valve with a well equipped with an instrumental take-off, essential for the tightness test of the system. This element can be crucial in case of inspections and safety checks and certainly facilitates the maintenance of the R1K 50 boiler.

In fact, during the maintenance of the appliance, it is mandatory to perform a suitable test like UNI 11137:2019 that verifies the correct tightness of the gas system.

Flushing the Heating System

Flushing the heating system is crucial to prevent clogging of the primary exchanger of the Radiant R1K 50 boiler. Over time, especially in cast iron or aluminum systems, a metallic sludge can form that can clog the narrow passages of the exchanger.

After flushing the system, it is highly recommended to install a magnetic sludge filter on the Radiant R1K 50 boiler. This filter plays an essential role in protecting the exchanger from the buildup of dirt and debris, ensuring greater efficiency and longevity of the heating system.

Additional improvements can include the installation of an advanced thermostat with relay function. This device allows for more effective management of heating hours, helping to optimize energy consumption.

Suggested Accessories

To optimize the functionality and efficiency of your R1K 50 boiler, there are various accessories that we recommend considering:

  • Programmable Thermostat: Regulates ambient temperature on a daily or weekly basis. The advanced new generation models also offer remote control and advanced programming.
  • Magnetic Filter Dirt Separator: An essential device for keeping the hydraulic circuit clean, removing both magnetic and non-magnetic impurities and debris.

Magnetic Filter for Heating

Considered the best accessory to block the entry of dust and debris from the heating system into the device.

The decision to install a magnetic filter on the heating return line is an important one to maintain the effectiveness and reliability of the boiler. This component is essential for filtering debris that could otherwise accumulate and hinder the proper functioning of the boiler, particularly regarding the primary exchanger and the diverter valve. It's important to choose a high-quality filter and ensure it is correctly installed to fully benefit from its advantages.

No items found.

Room Thermostat and Programmable Thermostat

For optimal temperature control in your home, consider installing a thermostat or programmable thermostat for your boiler.

These devices allow you to regulate and program the temperature precisely, adjusting it to your daily needs. A programmable thermostat, in particular, offers the possibility to set different programs for specific days and times, optimizing comfort and reducing energy costs.

There are various models available, including:

  • Daily Programmable Thermostats
  • Weekly Programmable Thermostats
  • New Generation Thermostats with Remote Control

The choice of model depends on your specific needs and the configuration of your heating system.

Daily Environmental Thermostat: Regulatory Compliance and Economy

The daily environmental thermostat is the ideal solution for complying with regulations requiring at least two temperature levels within 24 hours, combining efficiency and simplicity.

This device ensures the ability to set different temperature levels throughout the day, perfectly adapting to various needs and contributing to energy savings. Its ease of use makes it suitable for all ages, including seniors.

  • Flexible programming and compliance with regulations
  • Easy to use for all age groups
  • Affordable cost and great added value

An economical and functional option for those looking for effective home temperature control without complexity.

No items found.
No items found.

Weekly Programmable Thermostat

For advanced and personalized home temperature management, the weekly programmable thermostat is an excellent choice.

This device allows for setting different temperatures for various days of the week, perfectly adapting to different weekly routines. It is ideal for those who need detailed heating control, with the ability to set lower temperatures on days when the home is empty and higher when it is occupied.

Key features of the weekly programmable thermostat include:

  • Flexible programming for each day of the week
  • Advanced energy-saving functions
  • Intuitive user interface for easy programming

A weekly programmable thermostat is perfect for those seeking a balance between comfort, convenience, and energy efficiency, providing precise control of the home climate.

No items found.
No items found.

Advanced New Generation Thermostats

New generation advanced thermostats offer cutting-edge technologies for optimal home climate control.

These devices stand out for their learning capability and adaptation to user habits, automatically adjusting the temperature based on daily and seasonal patterns. With features like remote control via smartphone and integration with home automation systems, they offer an unprecedented level of convenience and energy efficiency.

Salient features of these thermostats include:

  • Wi-Fi connectivity and remote control
  • Integration with voice assistants and smart home systems
  • Learning algorithms for automatic temperature optimization

For those seeking the utmost efficiency, convenience, and personalization in home temperature control, an advanced new generation thermostat is the ideal choice.

No items found.
No items found.

INFO MENU DISPLAY DATA

To view the boiler data from info menu you just have to press the INFO key. The info code will be displayed on the left side of the screen and its relative value will be displayed on the centre of the screen.
Use keys ‘ + ’ and ‘ - ’ of the heating circuit to scroll through the list of displayed data. To exit display mode press the INFO ‘ i ’ key.

Info Code Description
D0 domestic Circuit Probe Temperature
D1 external Probe Temperature
D2 fan Speed
D3 bottom Area Probe Temperature [if Area Board Installed]
D4 return Probe Temperature
D5 solar Collector Temperature [if Solar Board Installed] (Scs)
D6 solar Boiler Temperature (Bottom) [if Solar Board Installed] (Sbsi)
D7 solar Boiler Temperature (Top) [if Solar Board Installed] (Sbss)
D8 solar Collector Probe Temperature 2 [if Solar Board Installed] (Scs2)
D9 extra Solar Boiler Temperature [if Solar Board Installed] (Sbs3)

Anomaly Reporting Codes R1K 50

To display the last 5 anomaly reporting codes, from the most recent in chronological order, activate OFF mode using the central button and hold down the INFO button for 5 seconds. To scroll through the list of stored anomalies, use the PLUS and MINUS buttons of the heating system. To reset the anomaly history, press the RESET button. To exit the display environment, press the INFO button.

Anomaly Code Possible Cause Remedy Reset
E01 Flame lock without flame ignition
  • No gas; Check the supply network
  • Broken or grounded ignition electrode; Replace it
  • Broken gas valve; Replace it
  • Slow ignition set too low; Adjust the minimum or slow ignition
  • Inlet pressure too high (only for LPG boilers); Check the maximum regulation pressure
Manual reset (Press the reset button)
E02 Safety thermostat (95°C)
  • Broken or disconnected thermostat cable; Check the electrical connection
  • Broken thermostat; Replace it
Manual reset (Press the reset button)
E03 Safety thermal fuse for fumes (102°C)
  • Broken thermal fuse; Replace it
  • Disconnected thermal fuse cable; Check the electrical connection
Manual reset (Press the reset button)
E04 Water shortage in the system
  • Insufficient water pressure in the system (below 0.3 bar); Fill the system
  • Disconnected water pressure switch cable; Check the electrical connection
  • Broken water pressure switch; Replace it
Automatic
E05 Heating sensor
  • Broken or uncalibrated sensor (Resistance value 10 kOhm at 25 °C NTC); Replace it
  • Wet or disconnected sensor connector; Check the electrical connection
Automatic
E06 Sanitary sensor
  • Broken or uncalibrated sensor (Resistance value 10 kOhm at 25 °C NTC); Replace it
  • Wet or disconnected sensor connector; Check the electrical connection
Automatic
E15 Return sensor
  • Broken or uncalibrated sensor (Resistance value 10 kOhm at 25 °C NTC); Replace it
  • Wet or disconnected sensor connector; Check the electrical connection
Automatic
E16 Fan
  • Broken fan board; Replace it
  • Broken fan; Replace it
  • Malfunctioning electrical supply cable; Replace it
Automatic
E18 Insufficient circulation
  • Clogged heat exchanger; Clean the heat exchanger or replace it
  • Broken circulator or dirty impeller; Clean the impeller or replace the circulator
Automatic
E21 Generic internal board error Incorrect signal recognition by the microprocessor of the modulation board; If the modulation board does not reset the error automatically, replace it Automatic
E22 Parameter programming request Memory loss of the microprocessor; Reprogram parameters Manual reset (Remove power)
E35 Parasitic flame
  • Malfunctioning detection electrode; Clean or replace it
  • Malfunctioning detection electrode cable; Replace it
  • Malfunctioning modulation board; Replace it
Manual reset (Press the reset button)
E40 Power supply voltage Power supply voltage out of operating range (below 160 volts); Check the electrical supply network (The error deactivates automatically as soon as the power supply voltage returns within the required limits) Automatic

Common Questions and Answers About the Boiler

Here is a list of common questions and answers that we frequently receive about the Radiant R1K 50 boiler model. This section will help you better understand the features, functionality, and maintenance of your appliance.

Loud Noises During Operation

If your Radiant R1K 50 boiler makes loud noises during operation, first check the system pressure. Too low a pressure can be the cause. Otherwise, in this condensing boiler, it could occur due to lack of maintenance.

Indeed, the heat exchanger tends to slightly oxidize during operation and over time a large amount of dirt can accumulate in the condensate siphon. Regular maintenance is essential to reduce the risk of noises or machine shutdowns.

Opentherm Protocol Support by the Boiler

YES: The boiler is equipped with non-powered thermostatic connections, compatible with Smart Thermostats or Remote Controls. This allows the use of advanced functions such as:

  • Adjusting the domestic hot water temperature: Ideal for R1K 50 boilers installed in hard-to-reach areas.
  • Adjusting the radiator temperature: With the Opentherm chronothermostat, it is possible to adjust the radiator temperatures directly from the boiler.
  • Setting operating times for domestic hot water: A feature that helps to reduce the maintenance costs of the boiler for models with storage tanks.
  • Fault Management: Using the Opentherm 2 protocol or a specific remote control from Radiant.
  • etc...

Pressing the buttons to adjust the heating, the temperature does not change.

The button panel is sensitive to repeated presses after years of operation. Often, the malfunction of the adjustment buttons is due to the absence of a thermostat, which has led to the exclusive use of the boiler's buttons.

In light of this, it is suggested to install a new control board to restore the correct functioning of the button panel, but also to integrate a thermostat to continue adjusting the heating from another, more reliable, and less expensive device.