The Radiant R2K 24 RAIN model represents a cutting-edge in the field of condensing boilers, thanks to its ABS casing designed to withstand the most adverse weather conditions, ideal for outdoor installations.

This condensing boiler not only uses the latent heat of water vapor to improve energy efficiency, but also offers the robustness and durability of the ABS exterior jacket. The choice of this material ensures effective protection against rain and moisture, guaranteeing consistent performance and reducing the need for maintenance over time.

Annual Maintenance and Safety

To ensure that the boiler maintains its safety and efficiency performance, it is essential to subject it to regular maintenance every year. The annual review is vital to ensure the safety and proper ongoing operation of the device.

Boiler Checklist: Winter Preparation

  • Boiler Pressure Check: Verify the pressure via the pressure gauge to ensure optimal performance.
  • Thermostat Management: Check the batteries of the thermostat for accurate temperature regulation.
  • System Pressure: Ensure that the heating system pressure is appropriate, between 1 and 1.5 bar.
  • Professional Maintenance: Schedule professional maintenance for cleaning and inspection of your Radiant R2K 24 RAIN boiler.

Maintaining Heating System Pressure

It's essential to check the heating system's pressure quarterly, ensuring it's between 1bar and 2bar. This check should not be neglected even during the summer months, as the radiator water is used for hot water production. A drop in pressure can interrupt the boiler's operation.

To adjust the pressure, use the filling tap under the appliance. Open it to bring the pressure to 1.5bar, then close it.

Suggested Temperatures

The Radiant R2K 24 RAIN boiler can always produce the temperature you want for heating according to your needs. You can adjust the temperatures via the control panel, but we suggest setting the hot water temperature (DHW) to the minimum necessary due to limescale and domestic hot water (DHW) considerations.

Attention to temperature settings:

  • The heating temperature setting refers to the radiator temperature, not the ambient temperature.
  • The domestic hot water temperature setting should be kept as low as possible to avoid calcification inside the secondary heat exchanger.

Preventing Limescale in Showers: Filters and Shower Heads

Preventing limescale buildup in shower head aerator filters is crucial for maintaining an efficient sanitary system. Excessive buildup can complicate the removal of aerators and lead to unwanted overheating. We recommend regular replacement of these elements to preserve the functionality of the Radiant R2K 24 RAIN boiler.

No items found.

Getting Your Boiler Ready for Vacation

Before leaving for a vacation, it's vital to ensure that your Radiant R2K 24 RAIN boiler is ready and safe. This is important even for the most advanced boiler models.

Recommended procedure:

  • Stop the hot water supply to prevent leaks.
  • Shut off the gas supply as a safety precaution.
  • Deactivate the heat generator to avoid wasting energy and increase safety.

Upon your return, restore the functions in reverse order. You may need to restart the heat generator to resolve errors related to the prolonged shutdown.

By following these steps, you can relax on vacation knowing that your boiler is in a safe state.

Boiler Usage Warnings

To ensure the safety, efficiency, and performance of the R2K 24 RAIN appliance, annual maintenance is crucial. It is highly discouraged to intervene inside the boiler without adequate technical skills. In case of anomalies or malfunctions, it is important to always consult a qualified technician. Annual maintenance by specialized personnel is essential for the safety and continuous functioning of the appliance.

Safety in the Use of Electric Energy

It is essential to adopt precautions when using the R2K 24 RAIN boiler to avoid risks:

  • Do not handle the appliance with wet or damp hands, nor walk barefoot in its vicinity.
  • Handle electrical cords carefully to avoid damage and malfunctions.
  • Do not leave the appliance outdoors exposed to rain or sun, unless it is specifically designed for this purpose.
  • If the cord is damaged, immediately turn off the appliance and contact a qualified technician.

Remember that only authorized personnel should install and maintain the appliance. Unauthorized maintenance or improper use can invalidate the warranty and compromise safety.

What to Do in the Presence of Gas Odor

In situations of potential gas leakage, it is crucial to follow these guidelines:

  • Avoid using any electrical device that could trigger sparks, including the phone.
  • Immediately ventilate the environment by opening doors and windows.
  • Close the gas taps to stop the leakage.
  • Promptly call for urgent intervention by expert and qualified personnel.

The boiler should be used exclusively according to the manufacturer's instructions and for heating water to safe temperatures. Improper use can cause serious damage. Ensure that installation and maintenance are entrusted to authorized technicians to avoid risks and ensure compliance with safety regulations.

List of Components and Spare Parts

In this guide, you will discover everything there is to know about the different components and spare parts of the R2K 24 RAIN boiler: how to identify them, their specific function, and useful tips for maintenance and replacement.

Temperature Adjustment

On the control panel of the Radiant R2K 24 RAIN condensing boiler, you can find all the operational information. You can set the temperatures for heating or hot water by pressing the + and - buttons next to their respective symbols: Faucet and Radiator. After pressing, the boiler displays the set temperature for only a few seconds.

Normally, the boiler shows the flow temperature, to be interpreted as the internal temperature of the boiler. As a result, you will see the temperature rise even in summer when the Radiant R2K 24 RAIN boiler produces hot water, while in winter it can be interpreted as the current temperature of the radiators.

Using the + and - buttons at the top for heating and at the bottom for domestic hot water, you can choose the desired temperatures for heating. We suggest:

  • From 25°C to 38°C if you have underfloor heating.
  • From 55°C to 65°C if you have radiators made of aluminum or steel.
  • From 45°C to 60°C if you have cast iron radiators.

For domestic hot water, you can choose the temperature using the + and - buttons at the bottom. We suggest a temperature between 38 and 45°C.

The general advice for the temperature of domestic hot water is to keep it as low as possible, especially if your water supply provides very hard water (over 30°F).

Boiler Circulator Radiant R2K 24 RAIN

Energy Saving with the Modulating Pump for Boilers

The introduction of variable speed modulating pumps in modern boilers is a revolution in terms of energy saving and cost reduction. These pumps, regulated by an advanced electronic system through a second connector, are capable of varying their speed from 0 to 100% according to the real needs, maximizing the efficiency of the system. Their use, mandatory in new boilers, demonstrates a commitment to solutions that combine excellent performance with care for the environment and household economy.

3/8 Automatic Plastic Air Purger for Radiant R2K 24 RAIN boiler

Automatic Plastic Air Purger

The plastic automatic air purger, used as an insert in the purging housing in the pump manifold, is a key component in the Radiant R2K 24 RAIN boiler. This small element plays a vital role in ensuring the efficiency of the heating system by eliminating air from the system.

Made of durable plastic, this air purger is designed to easily fit into the dedicated housing in the pump manifold. Its use is particularly recommended to prevent air accumulation in the boiler's hydraulic circuitry, especially in systems with a lot of aluminum where this problem is more frequent after periods of inactivity (summer).

Regularly checking and replacing the air purger and the system pressure is essential for maintaining uninterrupted operation at the start of the heating season. Its functionality is crucial for the proper operation of the entire domestic heating system.

3/8 Automatic Air Purger for Radiant R2K 24 RAIN boiler

3/8 Automatic Air Purger

The 3/8 automatic air purger is a fundamental component in the Radiant R2K 24 RAIN boiler to ensure the elimination of air in the heating system. This small but essential device plays a critical role in maintaining the efficiency of the heating system.

Despite its low cost, this component is vital to ensure that there is no trapped air in the radiator system, especially for aluminum ones, where the presence of air can be a frequent problem, particularly after long periods of inactivity like during the summer.

Checking the functionality and replacing the air purger is always advised to prevent circulation problems at the beginning of the heating season. Its efficiency is crucial for the proper operation of the entire domestic heating system.

Safety Systems according to the ErP Directive

The construction and installation of boilers in Europe are strictly regulated by a series of European standards, aimed at ensuring safety, energy efficiency, and reduction of environmental impact.

One of the main reference regulations is the ErP (Energy-related Products) Directive, which imposes stringent requirements in terms of energy efficiency and emissions for all energy-related products, including boilers. This directive is accompanied by specific UNI EN standards for each type of boiler, detailing the technical and safety standards to be respected.

The R2K 24 RAIN boiler therefore includes:

The Safety Thermostat, located on the heating supply, intervenes by blocking the gas flow to the burner in case of overheating of the water in the primary circuit. It is essential to never deactivate this safety device.

The Flame Ionization Detector ensures safety by shutting down the boiler in case of gas absence or incomplete ignition of the main burner.

The Antifreeze Device activates the burner to maintain the water temperature above 5 °C, preventing freezing of the system.

The Hydraulic Safety Valve, set at 3 bar, protects the heating circuit. It is advisable to connect it to a siphoned drain and not use it to empty the circuit.

Possible Improvement Works

The condensing boiler Radiant R2K 24 RAIN requires special attention to the correct installation of the flue pipe. Especially in horizontal sections, condensation can form, compromising the functionality of the fan. It is not uncommon to see installations where the flue pipe (especially if corrugated) forms a siphon, causing the boiler to produce very loud noises. It is essential to have a qualified technician ensure that the pipes are in optimal condition.

Integrating a Gas Tap with a Test Well

Not always does the meter provide a connection for instrumental tightness testing. A useful tip is to replace the gas tap under the boiler with a valve with a well equipped with an instrumental take-off, essential for the tightness test of the system. This element can be crucial in case of inspections and safety checks and certainly facilitates the maintenance of the R2K 24 RAIN boiler.

In fact, during the maintenance of the appliance, it is mandatory to perform a suitable test like UNI 11137:2019 that verifies the correct tightness of the gas system.

Flushing the Heating System

Flushing the heating system is crucial to prevent clogging of the primary exchanger of the Radiant R2K 24 RAIN boiler. Over time, especially in cast iron or aluminum systems, a metallic sludge can form that can clog the narrow passages of the exchanger.

After flushing the system, it is highly recommended to install a magnetic sludge filter on the Radiant R2K 24 RAIN boiler. This filter plays an essential role in protecting the exchanger from the buildup of dirt and debris, ensuring greater efficiency and longevity of the heating system.

Additional improvements can include the installation of an advanced thermostat with relay function. This device allows for more effective management of heating hours, helping to optimize energy consumption.

Suggested Accessories

You might consider a range of accessories that would enhance the functionality of the R2K 24 RAIN boiler.

Magnetic Filter for Heating

Considered the best accessory to block the entry of dust and debris from the heating system into the device.

Installing the magnetic filter on the heating return line is a crucial step in ensuring the longevity of the boiler. This device effectively separates and retains any particles that could cause damage or inefficiencies in the device, including preventing blockage of the primary exchanger. Its presence also ensures less stress on the diverter valve, increasing its reliability and reducing the risk of malfunctions.

No items found.

Polyphosphate Dosing Pump

If the hardness of the tap water exceeds 20 French degrees, we suggest equipping the Radiant R2K 24 RAIN boiler with a polyphosphate doser.

Polyphosphates, available in powder or liquid form, are mixed with the cold water entering the Radiant R2K 24 RAIN boiler, significantly reducing limescale formation. These additives are essential for maintaining efficiency and extending the lifespan of the device and must be regularly replenished.

There are several models of polyphosphate dosers, the most common ones are:

  • Powder Polyphosphates
  • Liquid Polyphosphates

Each type of polyphosphate requires a specific system for mixing.

No items found.
No items found.

Integrated Solutions: Thermostat and Programmable Thermostat

For advanced and integrated control of the Radiant R2K 24 RAIN boiler, choose a latest generation room thermostat or programmable thermostat.

These devices offer sophisticated home temperature regulation, perfectly adapting to your lifestyle and needs. With programmable thermostats, you can easily set custom schedules for each day of the week, ensuring a consistently comfortable environment and optimizing energy consumption.

Select from a variety of models, including:

  • Daily Programmable Thermostats
  • Weekly Programmable Thermostats
  • Connected Thermostats for Remote Control

Your choice should complement the specifics of your Radiant R2K 24 RAIN boiler and your home.

Daily Environmental Thermostat: Regulatory Compliance and Economy

The daily environmental thermostat is the ideal solution for complying with regulations requiring at least two temperature levels within 24 hours, combining efficiency and simplicity.

This device ensures the ability to set different temperature levels throughout the day, perfectly adapting to various needs and contributing to energy savings. Its ease of use makes it suitable for all ages, including seniors.

  • Flexible programming and compliance with regulations
  • Easy to use for all age groups
  • Affordable cost and great added value

An economical and functional option for those looking for effective home temperature control without complexity.

No items found.
No items found.

Weekly Programmable Thermostat

For advanced and personalized home temperature management, the weekly programmable thermostat is an excellent choice.

This device allows for setting different temperatures for various days of the week, perfectly adapting to different weekly routines. It is ideal for those who need detailed heating control, with the ability to set lower temperatures on days when the home is empty and higher when it is occupied.

Key features of the weekly programmable thermostat include:

  • Flexible programming for each day of the week
  • Advanced energy-saving functions
  • Intuitive user interface for easy programming

A weekly programmable thermostat is perfect for those seeking a balance between comfort, convenience, and energy efficiency, providing precise control of the home climate.

No items found.
No items found.

Advanced New Generation Thermostats

New generation advanced thermostats offer cutting-edge technologies for optimal home climate control.

These devices stand out for their learning capability and adaptation to user habits, automatically adjusting the temperature based on daily and seasonal patterns. With features like remote control via smartphone and integration with home automation systems, they offer an unprecedented level of convenience and energy efficiency.

Salient features of these thermostats include:

  • Wi-Fi connectivity and remote control
  • Integration with voice assistants and smart home systems
  • Learning algorithms for automatic temperature optimization

For those seeking the utmost efficiency, convenience, and personalization in home temperature control, an advanced new generation thermostat is the ideal choice.

No items found.
No items found.

INFO MENU DISPLAY DATA

To view the boiler data from info menu you just have to press the INFO key. The info code will be displayed on the left side of the screen and its relative value will be displayed on the centre of the screen.
Use keys ‘ + ’ and ‘ - ’ of the heating circuit to scroll through the list of displayed data. To exit display mode press the INFO ‘ i ’ key.

Info Code Description
D0 domestic Circuit Probe Temperature
D1 external Probe Temperature
D2 fan Speed
D3 bottom Area Probe Temperature [if Area Board Installed]
D4 return Probe Temperature
D5 solar Collector Temperature [if Solar Board Installed] (Scs)
D6 solar Boiler Temperature (Bottom) [if Solar Board Installed] (Sbsi)
D7 solar Boiler Temperature (Top) [if Solar Board Installed] (Sbss)
D8 solar Collector Probe Temperature 2 [if Solar Board Installed] (Scs2)
D9 extra Solar Boiler Temperature [if Solar Board Installed] (Sbs3)

Anomaly Reporting Codes R2K 24 RAIN

To display the last 5 anomaly reporting codes, from the most recent in chronological order, activate OFF mode using the central button and hold down the INFO button for 5 seconds. To scroll through the list of stored anomalies, use the PLUS and MINUS buttons of the heating system. To reset the anomaly history, press the RESET button. To exit the display environment, press the INFO button.

Anomaly Code Possible Cause Remedy Reset
E01 Flame lock without flame ignition
  • No gas; Check the supply network
  • Broken or grounded ignition electrode; Replace it
  • Broken gas valve; Replace it
  • Slow ignition set too low; Adjust the minimum or slow ignition
  • Inlet pressure too high (only for LPG boilers); Check the maximum regulation pressure
Manual reset (Press the reset button)
E02 Safety thermostat (95°C)
  • Broken or disconnected thermostat cable; Check the electrical connection
  • Broken thermostat; Replace it
Manual reset (Press the reset button)
E03 Safety thermal fuse for fumes (102°C)
  • Broken thermal fuse; Replace it
  • Disconnected thermal fuse cable; Check the electrical connection
Manual reset (Press the reset button)
E04 Water shortage in the system
  • Insufficient water pressure in the system (below 0.3 bar); Fill the system
  • Disconnected water pressure switch cable; Check the electrical connection
  • Broken water pressure switch; Replace it
Automatic
E05 Heating sensor
  • Broken or uncalibrated sensor (Resistance value 10 kOhm at 25 °C NTC); Replace it
  • Wet or disconnected sensor connector; Check the electrical connection
Automatic
E06 Sanitary sensor
  • Broken or uncalibrated sensor (Resistance value 10 kOhm at 25 °C NTC); Replace it
  • Wet or disconnected sensor connector; Check the electrical connection
Automatic
E15 Return sensor
  • Broken or uncalibrated sensor (Resistance value 10 kOhm at 25 °C NTC); Replace it
  • Wet or disconnected sensor connector; Check the electrical connection
Automatic
E16 Fan
  • Broken fan board; Replace it
  • Broken fan; Replace it
  • Malfunctioning electrical supply cable; Replace it
Automatic
E18 Insufficient circulation
  • Clogged heat exchanger; Clean the heat exchanger or replace it
  • Broken circulator or dirty impeller; Clean the impeller or replace the circulator
Automatic
E21 Generic internal board error Incorrect signal recognition by the microprocessor of the modulation board; If the modulation board does not reset the error automatically, replace it Automatic
E22 Parameter programming request Memory loss of the microprocessor; Reprogram parameters Manual reset (Remove power)
E35 Parasitic flame
  • Malfunctioning detection electrode; Clean or replace it
  • Malfunctioning detection electrode cable; Replace it
  • Malfunctioning modulation board; Replace it
Manual reset (Press the reset button)
E40 Power supply voltage Power supply voltage out of operating range (below 160 volts); Check the electrical supply network (The error deactivates automatically as soon as the power supply voltage returns within the required limits) Automatic

FAQ

Discover the answers to the most frequent questions about the Radiant R2K 24 RAIN boiler model. This quick guide has been compiled to provide clear and direct information based on the common questions from our users.

Hot Water takes forever to reach the shower/bathroom !!

The delay in hot water reaching the bathroom is often caused by a buildup of dirt in the aerator or showerhead holes. This buildup can reduce water flow, consequently slowing down the flow of hot water in the pipes. Cleaning these accessories from limescale can usually restore the speed of the hot water arrival.

Additionally, if the pipes connecting the bathroom to the boiler are made of iron, they might absorb some of the water's heat, lengthening the time for hot water to arrive. The presence of iron pipes can thus affect the timing of hot water delivery to the bathroom.

Loud Noises During Operation

If your Radiant R2K 24 RAIN boiler makes loud noises during operation, first check the system pressure. Too low a pressure can be the cause. Otherwise, in this condensing boiler, it could occur due to lack of maintenance.

Indeed, the heat exchanger tends to slightly oxidize during operation and over time a large amount of dirt can accumulate in the condensate siphon. Regular maintenance is essential to reduce the risk of noises or machine shutdowns.

Opentherm Protocol Support by the Boiler

YES: The boiler is pre-equipped for a tension-free connection with an Advanced Thermostat or Remote Control. The functionalities offered include:

  • Control of domestic hot water temperature: Useful for R2K 24 RAIN boilers installed in less accessible locations.
  • Adjustment of radiator temperature: An advanced Opentherm chronothermostat allows communication of the desired radiator temperatures to the boiler.
  • Time scheduling for water heating: Beneficial for boilers with storage tanks, helping to reduce boiler maintenance costs, like gas.
  • Error Resolution: Through Opentherm 2 or with devices from Radiant.
  • etc...

Pressing the buttons to adjust the heating, the temperature does not change.

The button panel is sensitive to repeated presses after years of operation. Often, the malfunction of the adjustment buttons is due to the absence of a thermostat, which has led to the exclusive use of the boiler's buttons.

In light of this, it is suggested to install a new control board to restore the correct functioning of the button panel, but also to integrate a thermostat to continue adjusting the heating from another, more reliable, and less expensive device.

Manuali Scaricabili

Downloadable Manuals