Designed for compact spaces, the MEA 20 J 1996 by Euroterm is a quick instantaneous boiler.

Suitable for small and medium apartments, this boiler is already in use in many residential buildings.

This model, a category B, requires a ventilation hole in the installation room. It's important to note that it is not suitable for installation in bedrooms or bathrooms.

Annual Maintenance and Safety

To ensure that the boiler maintains its safety and efficiency performance, it is essential to subject it to regular maintenance every year. The annual review is vital to ensure the safety and proper ongoing operation of the device.

Boiler Checklist: Winter Preparation

  • Boiler Pressure Check: Verify the pressure via the pressure gauge to ensure optimal performance.
  • Thermostat Management: Check the batteries of the thermostat for accurate temperature regulation.
  • System Pressure: Ensure that the heating system pressure is appropriate, between 1 and 1.5 bar.
  • Professional Maintenance: Schedule professional maintenance for cleaning and inspection of your Euroterm MEA 20 J 1996 boiler.

Check the Heating System's Pressure

At least every quarter, ensure that the system's pressure is correct; it should be between 1bar and 2bar. Also check this in the summer, as the boiler uses radiator water (only in internal circulation) to heat domestic hot water. If the pressure is low, the boiler is equipped with a component that stops the production of heating or hot water.

Remember to use the filling tap, found under the appliance. Open it and check that the pressure gauge reaches 1.5bar, then close it.

Suggested Temperatures

The Euroterm MEA 20 J 1996 boiler can always produce the temperature you want for heating according to your needs. You can adjust the temperatures via the control panel, but we suggest setting the hot water temperature (DHW) to the minimum necessary due to limescale and domestic hot water (DHW) considerations.

Attention to temperature settings:

  • The heating temperature setting refers to the radiator temperature, not the ambient temperature.
  • The domestic hot water temperature setting should be kept as low as possible to avoid calcification inside the secondary heat exchanger.

Cleaning Shower Head and Aerator Filters

We suggest regularly maintaining shower head and aerator filters, which over time can become clogged with limescale. With the progression of scaling, the aerators become difficult to remove, and there is also overheating of the hot water temperature causing the Euroterm MEA 20 J 1996 boiler to frequently turn on and off. This is due to the wait for heat exchange between technical water and sanitary water.

Therefore, it's good to have these accessories to replace as needed and frequently:

No items found.

Getting Your Boiler Ready for Vacation

Before leaving for a vacation, it's vital to ensure that your Euroterm MEA 20 J 1996 boiler is ready and safe. This is important even for the most advanced boiler models.

Recommended procedure:

  • Stop the hot water supply to prevent leaks.
  • Shut off the gas supply as a safety precaution.
  • Deactivate the heat generator to avoid wasting energy and increase safety.

Upon your return, restore the functions in reverse order. You may need to restart the heat generator to resolve errors related to the prolonged shutdown.

By following these steps, you can relax on vacation knowing that your boiler is in a safe state.

Winter Configuration for the Euroterm MEA 20 J 1996 Boiler

The 1996 Euroterm MEA 20 J 1996 boilers feature an innovative temperature control knob with a red LED that signals the activation of winter mode. If the LED tends to turn off, indicating a malfunction, this can be caused by wear on the potentiometer. To solve, you can place a small thickness of cardboard between the knob and the panel or apply a dry spray on the contacts.

In the previous 1992 model, winter mode is activated with a square button. For the 1996 version, just turn the knob to the desired winter temperature, for example 4. If the heating does not start, check the household thermostat to ensure it is calling for heat.

Boiler Safety and Maintenance

It is important to subject the MEA 20 J 1996 boiler to annual maintenance to ensure its efficiency and safety. Interventions on the boiler by unqualified people are strongly discouraged, as they can compromise the safety of the appliance. For any problem or anomaly, it is essential to turn to an expert technician. Remember that periodic maintenance by professionals is crucial for the longevity and safety of the appliance.

Safety Regulations for Electric Energy

Safety in the use of the MEA 20 J 1996 boiler requires adherence to specific rules:

  • Avoid contact with the appliance in the presence of moisture or while barefoot.
  • Do not force or pull electrical cords, to prevent risks of short circuit or damage.
  • Protect the appliance from atmospheric agents if not specifically indicated for outdoor use.
  • In case of faults in the cord, stop using and rely on a specialized technician for repairs.

It is also important that any installation, initial ignition, and maintenance is carried out by qualified and authorized technicians to ensure proper functioning and compliance with the warranty. Use not in accordance with the instructions can be dangerous and invalidate the manufacturer's liability.

What to Do in the Presence of Gas Odor

In situations of potential gas leakage, it is crucial to follow these guidelines:

  • Avoid using any electrical device that could trigger sparks, including the phone.
  • Immediately ventilate the environment by opening doors and windows.
  • Close the gas taps to stop the leakage.
  • Promptly call for urgent intervention by expert and qualified personnel.

The boiler should be used exclusively according to the manufacturer's instructions and for heating water to safe temperatures. Improper use can cause serious damage. Ensure that installation and maintenance are entrusted to authorized technicians to avoid risks and ensure compliance with safety regulations.

List of Components and Spare Parts

In this guide, you will discover everything there is to know about the different components and spare parts of the MEA 20 J 1996 boiler: how to identify them, their specific function, and useful tips for maintenance and replacement.

Giannoni Type F Diverter Valve Component for Boiler Euroterm MEA 20 J 1996

Features of the Giannoni Type F Diverter Valve

In the Euroterm MEA 20 J 1996 boiler, the Giannoni Type F Diverter Valve is essential for detecting and managing the flow of hot water. Sensitive to impurities like dirt and sludge, we recommend the use of a magnetic dirt separator filter for protection. Additionally, to ensure proper functionality under low water pressure conditions, it is important to keep aerators and showerheads clean.

Flat Primary Heat Exchanger for Boiler Euroterm MEA 20 J 1996

Maintenance of the Primary Heat Exchanger

The copper primary heat exchanger of the Euroterm MEA 20 J 1996 boiler is essential for thermal efficiency. Its large surface ensures effective and consistent heat transfer.

The overtemperature sensor closely monitors the system, helping to prevent risk conditions such as overheating.

Pipe blockages are one of the most common causes of malfunctions. It is advisable to consider the use of a Magnetic Filter to protect the exchanger from such blockages and ensure its longevity.

Anti-refoulaire flue cap for Euroterm MEA 20 J 1996 boiler

Adaptability of the Anti-Refoulaire Flue Cap

The anti-refoulaire flue cap for the Euroterm MEA 20 J 1996 boiler is a key element in the exhaust system, designed to fit perfectly with each specific boiler model.

Precisely assembled, its components made of sheet metal and rivets may require maintenance to prevent wear. In some cases, the use of screws for greater durability can be considered.

Attention: not all flue caps are interchangeable between different models. It is also important to monitor condensation, which can indicate drafting problems. Constant maintenance is fundamental to preserve the efficiency and safety of your Euroterm MEA 20 J 1996 boiler.

Expansion Vessel for Boiler Euroterm MEA 20 J 1996 CIMM CP387

CIMM CP387 Expansion Vessel for Boilers

The CIMM CP387 expansion vessel is designed to accurately regulate pressure in the Euroterm MEA 20 J 1996 boiler, with a durable design in red color and a standard 3/4-inch connection.

It is vital to perform periodic checks to maintain the efficiency of the expansion vessel, thereby preventing harmful pressure variations in the system.

Common problems include damage to the membrane and corrosion of the metal shell, which can negatively affect the operation of the heating system.

3/8 Automatic Air Purger for Euroterm MEA 20 J 1996 boiler

3/8 Automatic Air Purger

The 3/8 automatic air purger is a fundamental component in the Euroterm MEA 20 J 1996 boiler to ensure the elimination of air in the heating system. This small but essential device plays a critical role in maintaining the efficiency of the heating system.

Despite its low cost, this component is vital to ensure that there is no trapped air in the radiator system, especially for aluminum ones, where the presence of air can be a frequent problem, particularly after long periods of inactivity like during the summer.

Checking the functionality and replacing the air purger is always advised to prevent circulation problems at the beginning of the heating season. Its efficiency is crucial for the proper operation of the entire domestic heating system.

Brahma TM 11 Ignition Control Board for Boiler Euroterm MEA 20 J 1996

Brahma TM 11 Ignition Control Board

The Brahma TM 11 control board is fundamental for the proper functioning of type B boilers. This component oversees the ignition process, from managing the gas valve to the ignition and detection spark plugs, and the flame lock system. Its design, faithful to the original, ensures its availability on the market.

During ignition, the TM 11 receives electrical power and controls the process, from checking the flame lock system to activating the gas valve, culminating in ignition through the piezoelectric element.

An advantage of the TM 11 is its ability to support both single and double ignition, thus increasing burner efficiency.

Common problems are related to faults in the gas valve power relay, abnormal noises, and defects in the detection circuits.

Grundfos UPS15/60 Circulation Pump Boiler Euroterm MEA 20 J 1996

Grundfos UPS15/60 Pump Performance

Enhance the performance of your MEA 20 J 1996 boiler with the Grundfos UPS15/60 pump, designed for superior water circulation. Choose from three speed levels to maximize efficiency, with the third speed recommended for the best performance, except in the presence of circulation noises.

The pump, generally easy to install by a professional, may present difficulties in removing the stator from the cast iron head after a long period of use.

Technical specifications of the Grundfos UPS15/60:

  • Power Supply: 2.5 μF 230V - 50Hz IP44 TF 95
  • High Speed (III): 0.38 A - 85 W
  • Medium Speed (II): 0.30 A - 65 W
  • Low Speed (I): 0.21 A - 45 W

Suitable also as a replacement for models UPS 15-50, 15-60, 25-50, 25-60, 15-65, 25-65.

Safety systems are fundamental components in the design and operation of boilers. They ensure the correct functioning of the device, preventing dangerous situations for users and the environment.

The MEA 20 J 1996 boiler therefore includes:

The Safety Thermostat, located on the heating supply, intervenes by blocking the gas flow to the burner in case of overheating of the water in the primary circuit. It is essential to never deactivate this safety device.

The Flame Ionization Detector ensures safety by shutting down the boiler in case of gas absence or incomplete ignition of the main burner.

The Antifreeze Device activates the burner to maintain the water temperature above 5 °C, preventing freezing of the system.

The Hydraulic Safety Valve, set at 3 bar, protects the heating circuit. It is advisable to connect it to a siphoned drain and not use it to empty the circuit.

Possible Improvement Works

The Euroterm MEA 20 J 1996 boiler requires special attention to the flue pipes. It is essential to have a qualified technician ensure that the pipes are in optimal condition and comply with regulations.

Suitable Flue Pipes

The flue pipes for the Euroterm MEA 20 J 1996 boiler must comply with safety standards and be equipped with adequate seals to ensure efficiency and safety.

Stainless Steel Pipe for Boiler Unsuitable Aluminum Pipe Unsuitable White Enamel Pipe

Recent stainless steel pipes with seals are the recommended option. In contrast, corrugated aluminum pipes or white enamel pipes without seals are not up to standard. It is essential to regularly check the quality and condition of the flue pipes.

For further information and specific advice, it is recommended to consult a qualified technician and adhere to current regulations.

Integrating a Gas Tap with a Test Well

Not always does the meter provide a connection for instrumental tightness testing. A useful tip is to replace the gas tap under the boiler with a valve with a well equipped with an instrumental take-off, essential for the tightness test of the system. This element can be crucial in case of inspections and safety checks and certainly facilitates the maintenance of the MEA 20 J 1996 boiler.

In fact, during the maintenance of the appliance, it is mandatory to perform a suitable test like UNI 11137:2019 that verifies the correct tightness of the gas system.

Flushing the Heating System

Flushing the heating system is crucial to prevent clogging of the primary exchanger of the Euroterm MEA 20 J 1996 boiler. Over time, especially in cast iron or aluminum systems, a metallic sludge can form that can clog the narrow passages of the exchanger.

After flushing the system, it is highly recommended to install a magnetic sludge filter on the Euroterm MEA 20 J 1996 boiler. This filter plays an essential role in protecting the exchanger from the buildup of dirt and debris, ensuring greater efficiency and longevity of the heating system.

Additional improvements can include the installation of an advanced thermostat with relay function. This device allows for more effective management of heating hours, helping to optimize energy consumption.

Suggested Accessories

To optimize the functionality and efficiency of your MEA 20 J 1996 boiler, there are various accessories that we recommend considering:

  • Programmable Thermostat: Regulates ambient temperature on a daily or weekly basis. The advanced new generation models also offer remote control and advanced programming.
  • Magnetic Filter Dirt Separator: An essential device for keeping the hydraulic circuit clean, removing both magnetic and non-magnetic impurities and debris.

Magnetic Filter for Heating

Considered the best accessory to block the entry of dust and debris from the heating system into the device.

Installing the magnetic filter on the heating return line is a crucial step in ensuring the longevity of the boiler. This device effectively separates and retains any particles that could cause damage or inefficiencies in the device, including preventing blockage of the primary exchanger. Its presence also ensures less stress on the diverter valve, increasing its reliability and reducing the risk of malfunctions.

No items found.

Polyphosphate Dosing Pump

If the hardness of the tap water exceeds 20 French degrees, we suggest equipping the boiler with a polyphosphate doser.

This powder or liquid additive is proportionally mixed with the cold water entering the boiler and decreases the formation of limescale inside the device. Polyphosphates need to be replenished whenever they run out.

There are various models, but the most common ones are:

  • Powder Polyphosphates
  • Liquid Polyphosphates

Clearly, the type of polyphosphate requires a suitable mechanism for mixing.

No items found.
No items found.

Thermostat and Programmable Thermostat

Maximize comfort and efficiency of your Euroterm MEA 20 J 1996 boiler by installing a room thermostat or programmable thermostat.

These smart devices allow you to customize your home's temperature, ensuring a pleasant environment and reducing energy consumption. Particularly, programmable thermostats allow you to set different temperature settings for each day of the week or specific times of the day.

Available models include:

  • Daily Programmable Thermostats
  • Weekly Programmable Thermostats
  • Smart Thermostats with Remote Control

Choose the model that best meets the needs of your home and your Euroterm MEA 20 J 1996 boiler.

Daily Environmental Thermostat for Seniors

The daily environmental thermostat is particularly suitable for seniors, offering simple and immediate regulation of home temperature.

This device is ideal for those who desire an intuitive and uncomplicated control. Its daily programming allows for easy temperature adjustment to daily needs, making it particularly suitable for those who require a simple and reliable solution.

  • Simple and clear user interface
  • Easy temperature regulation
  • Compliant with energy efficiency regulations

The daily thermostat is an economical and functional solution, ideal for those needing direct and easy heating control.

No items found.
No items found.

Weekly Programmable Thermostat

For advanced and personalized home temperature management, the weekly programmable thermostat is an excellent choice.

This device allows for setting different temperatures for various days of the week, perfectly adapting to different weekly routines. It is ideal for those who need detailed heating control, with the ability to set lower temperatures on days when the home is empty and higher when it is occupied.

Key features of the weekly programmable thermostat include:

  • Flexible programming for each day of the week
  • Advanced energy-saving functions
  • Intuitive user interface for easy programming

A weekly programmable thermostat is perfect for those seeking a balance between comfort, convenience, and energy efficiency, providing precise control of the home climate.

No items found.
No items found.

Advanced New Generation Thermostats

New generation advanced thermostats offer cutting-edge technologies for optimal home climate control.

These devices stand out for their learning capability and adaptation to user habits, automatically adjusting the temperature based on daily and seasonal patterns. With features like remote control via smartphone and integration with home automation systems, they offer an unprecedented level of convenience and energy efficiency.

Salient features of these thermostats include:

  • Wi-Fi connectivity and remote control
  • Integration with voice assistants and smart home systems
  • Learning algorithms for automatic temperature optimization

For those seeking the utmost efficiency, convenience, and personalization in home temperature control, an advanced new generation thermostat is the ideal choice.

No items found.
No items found.

Common Questions and Answers About the Boiler

Here is a list of common questions and answers that we frequently receive about the Euroterm MEA 20 J 1996 boiler model. This section will help you better understand the features, functionality, and maintenance of your appliance.

The Water is Too Hot

If the water from your Euroterm MEA 20 J 1996 boiler is too hot, it may be due to reduced water flow, especially if you are on the upper floors of a building. Check that the tap filters and showerhead holes are clean. If the problem persists, consider cleaning the secondary exchanger or consult a plumber to evaluate the installation of a pressure booster system.

Heating Turns On with the Use of Domestic Hot Water

A common problem in the Euroterm MEA 20 J 1996 boiler is the activation of the heating system during the use of domestic hot water. This can be caused by hardening of the diverter valve or debris in the shutter. The solution involves replacing the diverter valve and installing a magnetic filter on the heating line to protect the new valve.

Loud Noises During Operation

If your Euroterm MEA 20 J 1996 boiler makes loud noises during operation, first check the system pressure. Too low a pressure can be the cause. Otherwise, it is advisable to contact a trusted technician for a thorough check.

Problems with the Knobs

If the knobs on your Euroterm MEA 20 J 1996 boiler are flickering and the heating does not stay on, check that the thermostat is calling for heat and that the batteries are charged. The flickering may be caused by wear on the potentiometer of the knob. Follow the indicated steps for a resolution attempt, or consider using a dry spray for electrical contacts on the potentiometers of the knobs with the help of a qualified technician.

Downloadable Manuals